16.4.3 Watchdog Timer Status Register
Register Name: WDT_SR
Access Type: Read-only
WDUNF: Watchdog Underflow
0: No Watchdog underflow occurred since the last read of WDT_SR.
1: At least one Watchdog underflow occurred since the last read of WDT_SR.
WDERR: Watchdog Error
0: No Watchdog error occurred since the last read of WDT_SR.
1: At least one Watchdog error occurred since the last read of WDT_SR.
Note:The WDD and WDV values must not be modified within a period of time of 3 slow clock periods following a restart of
the watchdog performed by means of a write access in the WDT_CR register, else the watchdog may trigger an end of
period earlier than expected.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––––
76543210
––––––WDERRWDUNF