Datasheet

Table Of Contents
565
SAM7S Series [DATASHEET]
6175M–ATARM–26-Oct-12
Note: 1. “Flash is in standby mode” means the Flash is not accessed at all.
Low power consumption figures found in the above table cannot be guaranteed when accessing the Flash in Ultra
Low Power Mode. In order to meet given low power consumption figures, it is recommended to either stop the pro-
cessor or jump to SRAM.
Active, Running out of SRAM, 1.1MHz
(SAM7S64/321/32/161/16)
Voltage regulator is on.
Brown Out Detector is activated.
Flash is in standby mode.
PLL is de-activated.
Main oscillator is activated.
ARM Core clock is 1.1 MHz.
Running out of SRAM
Analog-to-Digital Converter activated.
All peripheral clocks activated.
USB transceiver enabled.
onto AMP1
onto AMP2
1.12
1.06
mA
Active, Running out of SRAM, 1MHz
(SAM7S512/256/128)
Voltage regulator is on.
Brown Out Detector is activated.
Flash is in standby mode.
PLL is de-activated.
Main oscillator is activated.
ARM Core clock is 1 MHz.
Running out of SRAM
Analog-to-Digital Converter activated.
All peripheral clocks activated.
USB transceiver enabled.
onto AMP1
onto AMP2
1.06
0.99
mA
Ultra low power
Voltage regulator is in Low-power
mode.
Brown Out Detector is de-activated.
Flash is in standby mode.
(1)
PLL is de-activated.
Main oscillator is activated.
ARM Core in idle mode.
MCK @ 500Hz.
Analog-to-Digital Converter de-
activated.
All peripheral clocks de-activated.
USB transceiver disabled.
DDM and DDP pins connected to
ground.
onto AMP1
onto AMP2
34.3
4.0
µA
Table 37-7. Power Consumption for Different Modes
Mode Conditions Consumption Unit