6175M–ATARM–26-Oct-12
Active, running out of Flash, 32 MHz
(SAM7S64/321/32/161/16)
Voltage regulator is on.
Brown Out Detector is activated.
Flash is read.
PLL is activated.
ARM Core clock is 32 MHz.
Analog-to-Digital Converter activated.
All peripheral clocks activated.
USB transceiver enabled.
onto AMP1
onto AMP2
19.4
19.2
mA
Active, running out of Flash, 32 MHz
(SAM7S512/256/128)
Voltage regulator is on.
Brown Out Detector is activated.
Flash is read.
PLL is activated.
ARM Core clock is 32 MHz.
Analog-to-Digital Converter activated.
All peripheral clocks activated.
USB transceiver enabled.
onto AMP1
onto AMP2
20.6
20.4
mA
Active, running out of Flash, 48 MHz
(SAM7S64/321/32/161/16)
Voltage regulator is on.
Brown Out Detector is activated.
Flash is read.
PLL is activated.
ARM Core clock is 48 MHz.
Analog-to-Digital Converter activated.
All peripheral clocks activated.
USB transceiver enabled.
onto AMP1
onto AMP2
27.8
27.6
mA
Active, running out of Flash, 32 MHz
(SAM7S512/256/128)
Voltage regulator is on.
Brown Out Detector is activated.
Flash is read.
PLL is activated.
ARM Core clock is 48 MHz.
Analog-to-Digital Converter activated.
All peripheral clocks activated.
USB transceiver enabled.
onto AMP1
onto AMP2
29.5
29.3
mA
Table 37-7. Power Consumption for Different Modes
Mode Conditions Consumption Unit