Datasheet

Table Of Contents
521
SAM7S Series [DATASHEET]
6175M–ATARM–26-Oct-12
35.6.3 UDP Function Address Register
Register Name: UDP_ FADDR
Access Type: Read-write
FADD[6:0]: Function Address Value
The Function Address Value must be programmed by firmware once the device receives a set address request from the
host, and has achieved the status stage of the no-data control sequence. Refer to the Universal Serial Bus Specification,
Rev. 2.0 for more information. After power up or reset, the function address value is set to 0.
FEN: Function Enable
Read:
0 = Function endpoint disabled.
1 = Function endpoint enabled.
Write:
0 = Disables function endpoint.
1 = Default value.
The Function Enable bit (FEN) allows the microcontroller to enable or disable the function endpoints. The microcontroller
sets this bit after receipt of a reset from the host. Once this bit is set, the USB device is able to accept and transfer data
packets from and to the host.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––
–FEN
76543210
–FADD