START: Transmit Start Selection
STTDLY: Transmit Start Delay
If STTDLY is not 0, a delay of STTDLY clock cycles is inserted between the start event and the actual start of transmission
of data. When the Transmitter is programmed to start synchronously with the Receiver, the delay is also applied.
Note: STTDLY must be set carefully. If STTDLY is too short in respect to TAG (Transmit Sync Data) emission, data is emit-
ted instead of the end of TAG.
PERIOD: Transmit Period Divider Selection
This field selects the divider to apply to the selected Transmit Clock to generate a new Frame Sync Signal. If 0, no period
signal is generated. If not 0, a period signal is generated at each 2 x (PERIOD+1) Transmit Clock.
0x1 Transmit Clock enabled only if TF Low
0x2 Transmit Clock enabled only if TF High
0x3 Reserved
CKG Transmit Clock Gating
START Transmit Start
0x0
Continuous, as soon as a word is written in the SSC_THR Register (if Transmit is enabled), and
immediately after the end of transfer of the previous data.
0x1 Receive start
0x2 Detection of a low level on TF signal
0x3 Detection of a high level on TF signal
0x4 Detection of a falling edge on TF signal
0x5 Detection of a rising edge on TF signal
0x6 Detection of any level change on TF signal
0x7 Detection of any edge on TF signal