Figure 31-16. Receiver Time-out Block Diagram
Table 31-8 gives the maximum time-out period for some standard baud rates.
31.6.3.9 Framing Error
The receiver is capable of detecting framing errors. A framing error happens when the stop bit of a received char-
acter is detected at level 0. This can occur if the receiver and the transmitter are fully desynchronized.
A framing error is reported on the FRAME bit of the Channel Status Register (US_CSR). The FRAME bit is
asserted in the middle of the stop bit as soon as the framing error is detected. It is cleared by writing the Control
Register (US_CR) with the RSTSTA bit at 1.
Table 31-8. Maximum Time-out Period
Baud Rate Bit Time Time-out
bit/sec µs ms
600 1 667 109 225
1 200 833 54 613
2 400 417 27 306
4 800 208 13 653
9 600 104 6 827
14400 69 4 551
19200 52 3 413
28800 35 2 276
33400 30 1 962
56000 18 1 170
57600 17 1 138
200000 5 328
16-bit Time-out
Counter
0
TO
TIMEOUT
Baud Rate
Clock
=
Character
Received
RETTO
Load
Clock
16-bit
Value
STTTO
DQ
1
Clear