Datasheet

Table Of Contents
372
SAM7S Series [DATASHEET]
6175M–ATARM–26-Oct-12
31.6.3.4 Receiver Operations
When a character reception is completed, it is transferred to the Receive Holding Register (US_RHR) and the
RXRDY bit in the Status Register (US_CSR) rises. If a character is completed while the RXRDY is set, the OVRE
(Overrun Error) bit is set. The last character is transferred into US_RHR and overwrites the previous one. The
OVRE bit is cleared by writing the Control Register (US_CR) with the RSTSTA (Reset Status) bit at 1.
Figure 31-13. Receiver Status
D0 D1 D2 D3 D4 D5 D6 D7
RXD
Start
Bit
Parity
Bit
Stop
Bit
Baud Rate
Clock
Write
US_CR
RXRDY
OVRE
D0 D1 D2 D3 D4 D5 D6 D7
Start
Bit
Parity
Bit
Stop
Bit
RSTSTA = 1
Read
US_RHR