Datasheet

Table Of Contents
146
SAM7S Series [DATASHEET]
6175M–ATARM–26-Oct-12
Once the communication interface is identified, the application runs in an infinite loop waiting for
different commands as shown in Table 21-1.
Write commands: Write a byte (O), a halfword (H) or a word (W) to the target.
Address: Address in hexadecimal.
Value: Byte, halfword or word to write in hexadecimal.
Output: ‘>’.
Read commands: Read a byte (o), a halfword (h) or a word (w) from the target.
Address: Address in hexadecimal
Output: The byte, halfword or word read in hexadecimal following by ‘>’
Send a file (S): Send a file to a specified address
Address: Address in hexadecimal
Output: ‘>’.
Note: There is a time-out on this command which is reached when the prompt ‘>’ appears before the end of the command
execution.
Receive a file (R): Receive data into a file from a specified address
Address: Address in hexadecimal
NbOfBytes: Number of bytes in hexadecimal to receive
Output: ‘>’
•Go (G): Jump to a specified address and execute the code
Address: Address to jump in hexadecimal
Output: ‘>’
Get Version (V): Return the SAM-BA boot version
Output: ‘>’
Table 21-1. Commands Available through the SAM-BA Boot
Command Action Argument(s) Example
O write a byte Address, Value# O200001,CA#
o read a byte Address,# o200001,#
H write a half word Address, Value# H200002,CAFE#
h read a half word Address,# h200002,#
W write a word Address, Value# W200000,CAFEDECA#
w read a word Address,# w200000,#
S send a file Address,# S200000,#
R receive a file Address, NbOfBytes# R200000,1234#
G go Address# G200200#