Once the transmit queue is initialized, transmit is activated by writing to bit 9, the Transmit Start
bit of the network control register. Transmit is halted when a buffer descriptor with its used bit set
is read, or if a transmit error occurs, or by writing to the transmit halt bit of the network control
register. (Transmission is suspended if a pause frame is received while the pause enable bit is
set in the network configuration register.) Rewriting the start bit while transmission is active is
allowed.
Transmission control is implemented with a Tx_go variable which is readable in the transmit sta-
tus register at bit location 3. The Tx_go variable is reset when:
transmit is disabled
a buffer descriptor with its ownership bit set is read
a new value is written to the transmit buffer queue pointer register
bit 10, tx_halt, of the network control register is written
there is a transmit error such as too many retries or a transmit underrun.
To set tx_go, write to bit 9, tx_start, of the network control register. Transmit halt does not take
effect until any ongoing transmit finishes. If a collision occurs during transmission of a multi-
buffer frame, transmission automatically restarts from the first buffer of the frame. If a “used” bit
is read midway through transmission of a multi-buffer frame, this is treated as a transmit error.
Transmission stops, tx_er is asserted and the FCS is bad.
If transmission stops due to a transmit error, the transmit queue pointer resets to point to the
beginning of the transmit queue. Software needs to re-initialize the transmit queue after a trans-
mit error.
If transmission stops due to a “used” bit being read at the start of the frame, the transmission
queue pointer is not reset and transmit starts from the same transmit buffer descriptor when the
transmit start bit is written
Table 37-2. Transmit Buffer Descriptor Entry
Bit Function
Word 0
31:0 Byte Address of buffer
Word 1
31
Used. Needs to be zero for the EMAC to read data from the transmit buffer. The EMAC sets this to one for the first buffer
of a frame once it has been successfully transmitted.
Software has to clear this bit before the buffer can be used again.
Note: This bit is only set for the first buffer in a frame unlike receive where all buffers have the Used bit set once used.
30 Wrap. Marks last descriptor in transmit buffer descriptor list.
29 Retry limit exceeded, transmit error detected
28
Transmit underrun, occurs either when hresp is not OK (bus error) or the transmit data could not be fetched in time or
when buffers are exhausted in mid frame.
27 Buffers exhausted in mid frame
26:17 Reserved
16 No CRC. When set, no CRC is appended to the current frame. This bit only needs to be set for the last buffer of a frame.
15 Last buffer. When set, this bit indicates the last buffer in the current frame has been reached.
14:11 Reserved
10:0 Length of buffer