433
6120F–ATARM–03-Oct-06
AT91SAM7X512/256/128 Preliminary
or
If the waveform is center-aligned, then the output waveform period depends on the counter source clock and can be
calculated:
– By using the Master Clock (MCK) divided by an X given prescaler value (with X being 1, 2, 4, 8, 16, 32, 64, 128,
256, 512, or 1024). The resulting period formula will be:
– By using a Master Clock divided by one of both DIVA or DIVB divider, the formula becomes, respectively:
or
CRPD DIVA×()
MCK
------------------------------------------
CRPD DIVAB×()
MCK
----------------------------------------------
2 X CPRD××()
MCK
-----------------------------------------
2 CPRD DIVA××()
MCK
----------------------------------------------------
2 CPRD× DIVB×()
MCK
----------------------------------------------------