Datasheet

393
6120F–ATARM–03-Oct-06
AT91SAM7X512/256/128 Preliminary
Figure 32-8. WAVSEL = 10 Without Trigger
Figure 32-9. WAVSEL = 10 With Trigger
32.5.3.4 WAVSEL = 01
When WAVSEL = 01, the value of TC_CV is incremented from 0 to 0xFFFF. Once 0xFFFF is
reached, the value of TC_CV is decremented to 0, then re-incremented to 0xFFFF and so on.
See Figure 32-10.
A trigger such as an external event or a software trigger can modify TC_CV at any time. If a trig-
ger occurs while TC_CV is incrementing, TC_CV then decrements. If a trigger is received while
TC_CV is decrementing, TC_CV then increments. See Figure 32-11.
Time
Counter Value
R
C
R
B
R
A
TIOB
TIOA
Counter cleared by compare match with RC
0xFFFF
Waveform Examples
Time
Counter Value
R
C
R
B
R
A
TIOB
TIOA
Counter cleared by compare match with RC
0xFFFF
Waveform Examples
Counter cleared by trigger