Datasheet
316
4317K–AVR–03/2013
AT90PWM2/3/2B/3B
Figure 27-8. Idle Supply Current vs. V
CC
(Internal PLL Oscillator, 16 MHz)
27.2.1 Using the Power Reduction Register
The tables and formulas below can be used to calculate the additional current consumption for
the different I/O modules in Active and Idle mode. The enabling or disabling of the I/O modules
are controlled by the Power Reduction Register. See “Power Reduction Register” on page 43 for
details.
IDLE SUPPLY CURRENT vs. V
CC
INTERNAL PLL OSCILLATOR, 16 MHz
105 °C
85 °C
25 °C
-40 °C
0
1
2
3
4
5
6
7
8
9
22,533,544,555,5
V
CC
(V)
I
CC
(mA)
Table 27-1. Additional Current Consumption for the different I/O modules (absolute values)
PRR bit Typical numbers
V
CC
= 3V, F = 8MHz V
CC
= 5V, F = 16MHz
PRPSC2 350 uA 1.3 mA
PRPSC1 350 uA 1.3 mA
PRPSC0 350 uA 1.3 mA
PRTIM1 300 uA 1.15 mA
PRTIM0 200 uA 0.75 mA
PRSPI 250 uA 0.9 mA
PRUSART 550 uA 2 mA
PRADC 350 uA 1.3 mA