Datasheet
125
7734Q–AVR–02/12
AT90PWM81/161
12.14 PSC Input Mode 6: Stop signal, Jump to Opposite Dead-Time and Wait
Figure 12-31. PSC behavior versus PSCn Input A in Fault Mode 6.
Used in Fault mode 6, PSCn Input A or PSCn Input B act indifferently on On-Time0/Dead-Time0
or on On-Time1/Dead-Time1.
12.15 PSC Input Mode 7: Halt PSC and Wait for Software Action
Figure 12-32. PSC behavior versus PSCn Input A in Fault Mode 7.
Note: 1. Software action is the setting of the PRUNn bit in PCTLn register.
Used in Fault mode 7, PSCn Input A or PSCn Input B act indifferently on On-Time0/Dead-Time0
or on On-Time1/Dead-Time1.
PSCOUTn0
PSCOUTn1
DT0 OT0
DT1
OT1
DT0 OT0
DT1 OT1
DT0 OT0
DT1 OT1
PSCn Input A
or
PSCn Input B
PSCOUTn0
PSCOUTn1
DT0 OT0
DT1
OT1
DT0 OT0 DT0 OT0
DT1 OT1
Software Action (1)
PSCn Input A
or
PSCn Input B