7682C–AUTO–04/08
AT90CAN32/64/128
1 - stuff error interrupt: detection of more than 5 consecutive bits with the same
polarity.
Bit 2 – CERG: CRC Error General
Writing a logical one resets this interrupt flag.
0 - no interrupt.
1 - CRC error interrupt: the CRC check on destuffed message does not fit with the
CRC field.
Bit 1 – FERG: Form Error General
Writing a logical one resets this interrupt flag.
0 - no interrupt.
1 - form error interrupt: one or more violations of the fixed form in the CRC delimiter,
acknowledgment delimiter or EOF.
Bit 0 – AERG: Acknowledgment Error General
Writing a logical one resets this interrupt flag.
0 - no interrupt.
1 - acknowledgment error interrupt: no detection of the dominant bit in acknowledge
slot.
19.10.4 CAN General Interrupt Enable Register - CANGIE
Bit 7 – ENIT: Enable all Interrupts (Except for CAN Timer Overrun Interrupt)
0 - interrupt disabled.
1- CANIT interrupt enabled.
Bit 6 – ENBOFF: Enable Bus Off Interrupt
0 - interrupt disabled.
1- bus off interrupt enabled.
Bit 5 – ENRX: Enable Receive Interrupt
0 - interrupt disabled.
1- receive interrupt enabled.
Bit 4 – ENTX: Enable Transmit Interrupt
0 - interrupt disabled.
1- transmit interrupt enabled.
Bit 3 – ENERR: Enable MOb Errors Interrupt
0 - interrupt disabled.
1- MOb errors interrupt enabled.
Bit 7 6 5 4 3 2 1 0
ENIT ENBOFF ENRX ENTX ENERR ENBX ENERG ENOVRT CANGIE
Read/Write R/W R/W R/W R/W R/W R/W R/W R/W