Datasheet

798
32072H–AVR32–10/2012
AT32UC3A3
29.7.1 Control Register
Name:
CR
Access Type: Write-only
Offset: 0x00
Reset Value: 0x00000000
START: Start Conversion
Writing a one to this bit will begin an analog-to-digital conversion.
Writing a zero to this bit has no effect.
This bit always reads zero.
SWRST: Software Reset
Writing a one to this bit will reset the ADC.
Writing a zero to this bit has no effect.
This bit always reads zero.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––––
76543210
––––––STARTSWRST