Datasheet

76
32072H–AVR32–10/2012
AT32UC3A3
7.6.18 BOD33 Control Register
Name: BOD33
Access Type: Read/Write
Offset: 0xD4
Reset Value: 0x0000010X
KEY: Register Write protection
This field must be written twice, first with key value 0x55, then 0xAA, for a write operation to have an effect.
FCD: BOD33 Fuse calibration done
Set to 1 when LEVEL field has been updated by the Flash fuses after power-on reset or Flash fuses update
If one, the LEVEL value will not be updated again by Flash fuses
Can be cleared to allow subsequent overwriting of the value by Flash fuses
CTRL: BOD33 Control
0: BOD33 is off
1: BOD33 is enabled and can reset the chip
2: BOD33 is enabled and but cannot reset the chip. Only interrupt will be sent to interrupt controller, if enabled in the IMR
register.
3: BOD33 is off
LEVEL: BOD33 Level
This field sets the triggering threshold of the BOD33. See Electrical Characteristics for actual voltage levels.
Note that any change to the LEVEL field of the BOD33 register should be done with the BOD33 deactivated to avoid spurious
reset or interrupt.
31 30 29 28 27 26 25 24
KEY
23 22 21 20 19 18 17 16
-------FCD
15 14 13 12 11 10 9 8
------ CTRL
76543210
-- LEVEL