12.9 EBI Timings
These timings are given for worst case process, T = 85C, VDDCORE = 1.65V, VDDIO = 3V and 40 pF load capacitance.
Note: 1. The maximum frequency of the SMC interface is the same as the max frequency for the HSB.
Note: 1. hold length = total cycle duration - setup duration - pulse duration. “hold length” is for “ncs rd hold length” or “nrd hold length”.
Table 12-22. SMC Clock Signal.
Symbol Parameter Max
(1)
Units
1/(t
CPSMC
) SMC Controller Clock Frequency 1/(t
cpcpu
)MHz
Table 12-23. SMC Read Signals with Hold Settings
Symbol Parameter Min Units
NRD Controlled (READ_MODE = 1)
SMC
1
Data Setup before NRD High
12
ns
SMC
2
Data Hold after NRD High
0
SMC
3
NRD High to NBS0/A0 Change
(1)
nrd hold length * t
CPSMC
- 1.3
SMC
4
NRD High to NBS1 Change
(1)
nrd hold length * t
CPSMC
- 1.3
SMC
5
NRD High to NBS2/A1 Change
(1)
nrd hold length * t
CPSMC
- 1.3
SMC
6
NRD High to NBS3 Change
(1)
nrd hold length * t
CPSMC
- 1.3
SMC
7
NRD High to A2 - A25 Change
(1)
nrd hold length * t
CPSMC
- 1.3
SMC
8
NRD High to NCS Inactive
(1)
(nrd hold length - ncs rd hold length) * t
CPSMC
- 2.3
SMC
9
NRD Pulse Width nrd pulse length * t
CPSMC
- 1.4
NRD Controlled (READ_MODE = 0)
SMC
10
Data Setup before NCS High
11.5
ns
SMC
11
Data Hold after NCS High
0
SMC
12
NCS High to NBS0/A0 Change
(1)
ncs rd hold length * t
CPSMC
- 2.3
SMC
13
NCS High to NBS0/A0 Change
(1)
ncs rd hold length * t
CPSMC
- 2.3
SMC
14
NCS High to NBS2/A1 Change
(1)
ncs rd hold length * t
CPSMC
- 2.3
SMC
15
NCS High to NBS3 Change
(1)
ncs rd hold length * t
CPSMC
- 2.3
SMC
16
NCS High to A2 - A25 Change
(1)
ncs rd hold length * t
CPSMC
- 4
SMC
17
NCS High to NRD Inactive
(1)
ncs rd hold length - nrd hold length)* t
CPSMC
- 1.3
SMC
18
NCS Pulse Width ncs rd pulse length * t
CPSMC
- 3.6
32058KS–AVR32–01/12