Two-wire Digital Temperature Sensor
17
8585B–SEEPR–8/10
6.5. Lower Alarm Trip Register (16-bit Read/Write, Address = 03h)
The Lower Alarm Trip Register holds the user programmed lower temperature boundary trip point in 11-bit two’s
complement format (0.25°C resolution) that can be used to monitor ambient temperature in an operating window
(See Table 6-9 and Table 6-10). When temperature decreases below this trip point minus any hysteresis set or
increases to meet or exceed this trip point, then the
EVENT
pin is asserted (if enabled).
This register becomes read only if the Alarm Window Lock bit (WINLOCK) bit six in the configuration register is
set to a ‘1’.
Table 6-9. Lower Alarm Trip Register Bit Distribution
Bit 15 14 13 12 11 10 9 8
Symbol RFU SIGN ALMWINL
Default Value 0 0 0 0 0 0 0 0
R / W access R R R R/W R/W R/W R/W R/W
Bit 7 6 5 4 3 2 1 0
Symbol ALMWINL RFU
Default Value 0 0 0 0 0 0 0 0
R / W access R/W R/W R/W R/W R/W R/W R R
Table 6-10. Lower Alarm Trip Register Bit Description
Bit Symbol Description
15:13 RFU Reserved for future use. Read as ‘0’
12 SIGN Sign bit
0 = Ambient temperature is greater than or equal to 0°C
1= Ambient temperature is less than 0°C
11:2 ALMWINL Lower Alarm Trip temperature bits
Represented in two’s complement format
1:0 RFU Reserved for future use. Read as ‘0’