User manual

© 2008 Microchip Technology Inc. DS51675B-page 9
LIN SERIAL ANALYZER
USERS GUIDE REV2.0
Chapter 2. Getting Started – Quick Setup
2.1 HIGHLIGHTS
This chapter discusses:
Using the LIN Serial Analyzer for the First Time
Software Installation
Running LIN Serial Analyser Program
2.2 USING THE LIN SERIAL ANALYZER FOR THE FIRST TIME
The LIN Serial Analyser is shipped preprogrammed and ready for use. The user needs
to supply:
A wiring harness with appropriate connections to its system network
A power supply (nominal 13.8V)
Before making any connections, the software must be installed on the host system. The
user must have administrator level rights to install some of the required programs. For
more information, see Section 2.3 “Software Installation”.
Power is supplied either through the round, power plug or the terminal block. The
positive and negative terminals and power plug are common. Supplied power must be
in the range of 8.0V to 30.0V with a nominal value of 12.0-14.4V. Less than 5.0 mA of
current is required to power the LIN transceiver section of the unit.
Internal jumper, E1, configures the unit as either a master or slave node. A 1.0 k bus
pull-up resistor is enabled when E1 is connected across A and B. With the jumper
removed, an internal 30 k resistor is retained.
The unit is configured as a master node as shipped.
2.3 SOFTWARE INSTALLATION
All necessary files are contained on the Compact Disc (CD) supplied with the device.
2.3.1 Installing the LIN Serial Analyser Program
1. Run setup.exe from the CD.
2. Select Install when prompted and follow any instructions.
The PC host program is uninstalled with the control panel’s add/remove utility.
2.4 RUNNING LIN SERIAL ANALYSER PROGRAM
Before starting the LIN Serial Analyser software:
The analyzer must be connected to the PC by a USB cable
The analyzer must be powered up
The analyzer’s green USB and blue LIN lights will be on when these conditions are
met.
Note: The LIN Serial Analyser program requires the Microsoft
®
.NET Framework
version 2.0.