Datasheet

2011-2013 Microchip Technology Inc. DS20005049C-page 3
MCP73830/L
1.0 ELECTRICAL
CHARACTERISTICS
Absolute Maximum Ratings†
V
DD
...................................................................................7.0V
All Inputs and Outputs w.r.t. V
SS
............... -0.3 to (V
DD
+0.3)V
Maximum Junction Temperature, T
J
............Internally Limited
Storage temperature .....................................-65°C to +150°C
ESD protection on all pins
Human Body Model (1.5 kW in Series with 100 pF) 2kV
Machine Model (200 pF, No Series Resistance).............300V
† Notice: Stresses above those listed under “Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and functional operation of
the device at those or any other conditions above those
indicated in the operational listings of this specification
is not implied. Exposure to maximum rating conditions
for extended periods may affect device reliability.
DC CHARACTERISTICS
Electrical Specifications: Unless otherwise indicated, all limits apply for V
DD
= [V
REG
(Typical) + 0.3V] to 6V,
T
A
= -40°C to +85°C. Typical values are at +25°C, V
DD
= [V
REG
(Typical) + 1.0V]
Parameters Sym. Min. Typ. Max. Units Conditions
Supply Input
Input Voltage Range V
DD
3.75 6 V
Supply Current I
SS
0.6 2 µA Shutdown;
V
DD
V
STOP
- 300 mV
500 900 µA Charging
25 50 µA Standby; CE = V
DD
Battery Discharge Current
Output Reverse
Leakage Current
I
DISCHARGE
10 15 µA Charge Complete;
V
DD
is Present
0.5 µA Shutdown
(V
DD
V
BAT
, or V
DD
< V
STOP
)
0.5 µA Standby; CE = V
DD
Undervoltage Lockout
UVLO Start Threshold V
START
3.45 3.6 3.75 V V
DD
Low-to-High
UVLO Stop Threshold V
STOP
3.15 3.3 3.45 V V
DD
High-to-Low
UVLO Hysteresis V
HYS
300 mV
Voltage Regulation (Constant Voltage Mode)
Regulated Output
Voltage Options
V
REG
—4.20VV
DD
= [V
REG
(Typical)+1V]
I
OUT
= 30 mA
Output Voltage
Tole ra nce
V
RTOL
-0.75 0.75 % T
A
= -5°C to +55°C
Line Regulation V
BAT
/V
BAT
)/
V
DD
|
0.2 0.3 %/V V
DD
= [V
REG
(Typical)+1V] to
12V
I
OUT
= 30 mA
Load Regulation V
BAT
/V
BAT
|— 0.2 0.3 %I
OUT
= 30 mA - 150 mA
V
DD
= [V
REG
(Typical)+1V]
Supply Ripple
Attenuation
PSRR 52 dB I
OUT
= 30 mA, 10 Hz to 1 kHz
47 dB I
OUT
= 30 mA, 10 Hz to 10 kHz
Note 1: Not production tested. Ensured by design.