DS52085A-page 94 2013 Microchip Technology Inc.
See also Section 10.3.2 “Emulator-to-Target Communication Error
Actions”.
Invalid streaming data was been detected. Run time watch or trace data may no
longer be valid. Is recommended that you restart your debug session.
See the FAQ, “Data capture has become flaky. What is going on?”.
10.2.6 Hardware/Firmware Errors
For the errors below, read any instructions within your error message.
The 17.5 rail is unable to turn on. Please unplug the MPLAB REAL ICE and
reconnect. If the problem persists contact Microchip for assistance.
The SRAM has failed its self test. Please unplug the MPLAB REAL ICE and
reconnect. If the problem persists contact Microchip for assistance.
The FPGA has failed its self test. MPLAB IDE will attempt to download the latest
firmware.
Please do not disconnect the REAL ICE during the download process. If the
problem persists contact Microchip for assistance.
The Driver board is missing. Please unplug the MPLAB REAL ICE, make sure the
driver board is properly seated and reconnect. If the problem persists contact
Microchip for assistance.
The Main board serial EEPROM is missing. Please unplug the MPLAB REAL ICE
and reconnect. If the problem persists contact Microchip for assistance.
The Driver board serial EEPROM is missing. Please unplug the MPLAB REAL ICE
and reconnect. If the problem persists contact Microchip for assistance.
The DAC is missing. Please unplug the MPLAB REAL ICE and reconnect. If the
problem persists contact Microchip for assistance.
The Main boards' trigger IO expander is missing. Please unplug the MPLAB
REAL ICE and reconnect. If the problem persists contact Microchip for
assistance.
The Data pin I/O test failed. Please unplug the MPLAB REAL ICE and reconnect.
If the problem persists contact Microchip for assistance.
The Driver I/O expander is missing. Please unplug the MPLAB REAL ICE and
reconnect. If the problem persists contact Microchip for assistance.
The VPP generator could not set the proper voltage. Please unplug the MPLAB
REAL ICE and then reconnect. If problem persists, contact Microchip for
assistance.
The VDD generator could not set the proper voltage. Please unplug the MPLAB
REAL ICE and then reconnect. If problem persists, contact Microchip for
assistance.
The Clock or Data line has clamped the external voltage! Please remove your
target, probe the voltage levels and then reconnect.
Too much current has been drawn on VPP. Please disconnect your circuit, check
the MCLR line for shorts and then reconnect.
Too much current has been drawn on VDD. Please disconnect your circuit, check
the CLK and DATA lines for shorts and then reconnect.
Target Vdd not detected. Please ensure the target device is connect