RIErr0046: An error occurred while trying to read the stopwatch count. The
stopwatch count may not be accurate.
See Section 10.3.2 “Emulator-to-Target Communication Error Actions”.
RIErr0047: Bootloader download failed.
RIErr0048: Unable to set trace options.
See Section 10.3.3 “Emulator-to-PC Communication Error Actions”.
RIErr0049: Unable to open file for streaming data trace. Trace will be turned off.
The trace file cannot be opened.
1. Make sure the directory is not Read Only. Right click on it and check its
Properties. This file is located, by default, in:
C:\Program Files\Microchip\MPLAB IDE\REAL ICE.
2. Deselect and then reselect the emulator as the debug tool.
RIErr0050: Unable to set probe options.
See Section 10.3.3 “Emulator-to-PC Communication Error Actions”.
RIErr0051: Unrecognized trace data format received.
Data capture or Native trace has gotten out of sync with MPLAB IDE. First try to Halt,
Reset and then Run again. If this does not work:
1. Unplug and plug in the emulator.
2. Reconnect to the emulator in MPLAB IDE.
3. Check that the target speed is entered on the Clock tab of the Settings dialog.
4. Run again.
RIErr0052: The current REAL ICE hardware version %x, is out of date. This
version of MPLAB IDE will support only version %x or higher.
Did you click Cancel when asked to download the latest firmware? If so, you will need
to download it now. Select Debugger>Settings
, Configuration tab, and click Manual
Download. Select the highest number .jam file and click Open.
If you cannot find any files to download or if this does not work (corrupted file), you will
need to get the latest version of MPLAB IDE and install it. Find the latest MPLAB IDE
at www.microchip.com.
RIErr0053: Unable to get REAL ICE protocol versions.
See Section 10.3.3 “Emulator-to-PC Communication Error Actions”.
RIErr0054: MPLAB IDE's REAL ICE protocol definitions are out of date. You must
upgrade MPLAB IDE to continue.
Find the latest MPLAB IDE at www.microchip.com.
RIErr0055: Unable to set firmware suite version.
RIErr0056: Unable to get voltages from REAL ICE.
See Section 10.3.3 “Emulator-to-PC Communication Error Actions”.
RIErr0057: Loopback could not be completed.
Ensure that you are using the Standard driver board and not the High-Speed driver
board for loopback. Also, see Section 10.3.2 “Emulator-to-Target Communication
Error Actions”.
RIErr0058: Loopback internal setup failure.
Emulator power supply failure. Contact Microchip technical support.
RIErr0059: Loopback clock feedback failure.
RIErr0060: Loopback data feedback failure.
Trigger/port pin failure. Contact Microchip technical support.