Datasheet
2010 Microchip Technology Inc. DS21809G-page 3
24AA014/24LC014
TABLE 1-2: AC CHARACTERISTICS
AC CHARACTERISTICS
Industrial (I): TA = -40°C to +85°C, VCC = +1.7V to +5.5V
Automotive (E): T
A = -40°C to +125°C, VCC = +2.5V to +5.5V
Param.
No.
Symbol Characteristic Min. Max. Units Conditions
1FCLK Clock frequency —
—
100
400
kHz 1.7V VCC < 1.8V
1.8V V
CC 5.5V
2T
HIGH Clock high time 4000
600
—
—
ns 1.7V VCC < 1.8V
1.8V V
CC 5.5V
3T
LOW Clock low time 4700
1300
—
—
ns 1.7V VCC < 1.8V
1.8V V
CC 5.5V
4T
R SDA and SCL rise time (Note 1) —
—
1000
300
ns 1.7V VCC < 1.8V
1.8V V
CC 5.5V
5T
F SDA and SCL fall time (Note 1) —
—
1000
300
ns 1.7V VCC < 1.8V
1.8V V
CC 5.5V
6T
HD:STA Start condition hold time 4000
600
—
—
ns 1.7V VCC < 1.8V
1.8V V
CC 5.5V
7T
SU:STA Start condition setup time 4700
600
—
—
ns 1.7V VCC < 1.8V
1.8V V
CC 5.5V
8T
HD:DAT Data input hold time 0 — ns (Note 2)
9T
SU:DAT Data input setup time 250
100
—
—
ns 1.7V VCC < 1.8V
1.8V V
CC 5.5V
10 T
SU:STO Stop condition setup time 4000
600
—
—
ns 1.7V VCC < 1.8V
1.8V V
CC 5.5V
11 T
SU:WP WP setup time 4000
600
—
—
ns 1.7V VCC < 1.8V
1.8V V
CC 5.5V
12 T
HD:WP WP hold time 4700
600
—
—
ns 1.7V VCC < 1.8V
1.8V V
CC 5.5V
13 T
AA Output valid from clock (Note 2) —
—
3500
900
ns 1.7V VCC < 1.8V
1.8V V
CC 5.5V
14 T
BUF Bus free time: Time the bus must
be free before a new transmission
can start
4700
1300
—
—
ns 1.7V V
CC < 1.8V
1.8V V
CC 5.5V
16 T
SP Input filter spike suppression
(SDA and SCL pins)
—50ns(Note 1 and Note 3)
17 T
WC Write cycle time (byte or page) — 5 ms —
18 — Endurance 1M — cycles 25°C, V
CC = 5.5V, Block mode
(Note 4)
Note 1: Not 100% tested. C
B = total capacitance of one bus line in pF.
2: As a transmitter, the device must provide an internal minimum delay time to bridge the undefined region (minimum
300 ns) of the falling edge of SCL to avoid unintended generation of Start or Stop conditions.
3: The combined T
SP and VHYS specifications are due to new Schmitt Trigger inputs, which provide improved noise spike
suppression. This eliminates the need for a T
I specification for standard operation.
4: This parameter is not tested but ensured by characterization. For endurance estimates in a specific application, please
consult the Total Endurance™ Model which can be obtained from Microchip’s web site at www.microchip.com.