Error Codes 
Read Errors 
ASC ASCQ Description 
00  00  NO ADDITIONAL SENSE INFORMATION 
00  06  I/O PROCESS TERMINATED, PLAY OPERATION ABORTED 
00  11  AUDIO PLAY OPERATION IN PROGRESS 
00  12  AUDIO PLAY OPERATION PAUSE 
00  13  AUDIO PLAY OPERATION SUCCESSFULLY COMPLETED 
00  14  AUDIO PLAY OPERATION STOPPED DUE TO ERROR 
00  15  NO CURRENT AUDIO STATUS TO RETURN 
00 17 CLEANINF REQUESTED 
01 00 
NO INDEX/SECTOR SIGNAL 
02  00  NO SEEK COMPLETE 
04  00  LOGICAL UNIT NOT READY, CAUSE NOT REPORTABLE 
04  01  LOGICAL UNIT IS IN PROCESS OF BECOMING READY 
04  02  LOGICAL UNIT NOT READY, INITIALIZING CMD. REQUESTED 
04  03  LOGICAL UNIT NOT READY, MANUAL INTERVENTION REQUIRED 
04  07  LOGICAL UNIT NOT READY, OPERATION IN PROGRESS 
05  00  LOGICAL UNIT DOES NOT RESPOND TO SELECTION 
06  00  NO REFERENCE POSITION FOUND (medium may be upside down) 
08  00  LOGICAL UNIT COMMUNICATION FAILURE 
08  01  LOGICAL UNIT COMUUNICATION TIME-OUT 
08  02  LOGICAL UNIT COMMUNICATION PARITY ERROR 
08  03  LOGICAL UNIT COMMUNICATION CRC ERROR (ULTRA-DMA/32) 
09  00  TRACK FOLLOWING ERROR 
09  01  TRACKING SERVO FAILURE 
09  02  FOCUS SERVO FAILURE 
09  03  SPINDLE SERVO FAILURE 
0A  00  ERROR LOG OVERFLOW 
0B 00 WARNING 
0B 01 WARNING-SPECIFIED TEMPERATURE EXCEEDED 
0B 02 WARNING-ENCLOSURE DEGRADED 
10  00  ID CRC OR ECC ERROR 
11  01  UNRECOVERED READ ERROR 
11  02  ERROR TOO LONG TO CORRECT 
11  05  L-EC UNCORRECTABLE ERROR 
11  06  CIRC UNRECOVERED ERROR 
11  0F  ERROR READING UPC/EAN NUMBER 
11  10  ERROR – LOSS PF STREAMING 
12  00  ADDRESS MARK NOT FOUND FOR ID FIELD 
13  00  ADDRESS MARK NOT FOUND FOR DATA FIELD 
14  01  RECORD NOT FOUND 
14  05  RECORD NOT FOUND – RECOMMEND REASSIGNMENT 
14  06  RECORD NOT FOUND – DATA AUTO – REALLOCATED 
15  00  RANDOM POSITIONING ERROR 
15  01  MECHANICAL POSITIONING ERROR 
15  02  POSITIONING ERROR DETECTED BY READ OF MEDIUM 
17 00 RECOVERED DATA WITH NO EEOR CORRECTION APPLIED 
17  01  RECOVERED DATA WITH RETRIES 
17 02 RECOVERED DATA WITH POSITIVE HEAD OFFSET 
17 03 RECOVERED DATA WITH NEGATIVE HEAD OFFSET 
17 04 
RECOVERED DATA WITH RETIES AND/OR CIRC APPLIED 
17 05 
RECOVERED DATA USING PREVIOUS SECTOR ID 
18 00 RECOVERED DATA WITH ERROR CORRECTION APPLIED 
18  01  RECOVERED DATA WITH ERROR CORP. & RETRIES APPLIED 
18  03  RECOVERED DATA WITH CIRC 
18  04  RECOVERED DATA WITH L-EC 
1A  00  PARAMETER LIST LENGTH ERROR 
1B  00  SYNCHRONOUS DATA TRANSFER ERROR 