Radio-RRC:
Parameter
Setting
OUT0 mode
Select the function for output-0 (OUT0) signal the I/O connector.
0 = I/O, active when IN0 on Control-RRC is active (Control-RRC IN0-mode
setting must be in state I/O). (default)
1 = Keyer, output to the radio straight key input
2 = PTT, used as external PTT
3 = Connect, active when the SIP-connection is active
4 = On/Off, controlled by the ON/OFF button on this side
(*)
5 = Keyer PTT, active when CW is send via the keyer (can be used to key
a PA). If you set “key delay” in the Control-RRC this output will be
activate key delay ms before the actual CW-keying is started.