Keyer Settings (only Control-RRC)
A very powerful function for remote CW operation is implemented in the RRC-1258MkII. The
system is able to handle delays and jitter caused by Internet in a unique way. This function is
also dependant on the I/O configuration, see IO settings.
Parameter
Setting
Enable
Enable the CW-keyer function.
No = CW-keyer is off (default)
Yes = CW-keyer is on
Iambic
Set the CW-keyer iambic mode.
Old type, squeeze keyer
Mode-A
Mode-B (default)
Mode-B + auto-char-space
Paddle reverse
Set the reverse mode for the CW-paddle.
No, left paddle dot & right paddle dash (default)
Yes, left paddle dash & right paddle dot