Parameter
Setting
Unit ID (Banner)
Text, whatever you want, that will be shown at the
top of the web-page (within brackets). Used to
identify different units.
“empty” (default)
“text”
DHCP
Select between a fixed IP address and DHCP. Fixed
IP address is recommended.
No (default)
Yes
IP
IP-address (only when fixed IP-address is used)
192.168.0.236 (default)
nnn.nnn.nnn.nnn
Netmask
Net mask (only when fixed IP-address is used)
255.255.255.0 (default)
nnn.nnn.nnn.nnn
Gateway
Gateway (only when fixed IP-address is used)
192.168.0.1 (default)
nnn.nnn.nnn.nnn
Dns server
DNS-address (only when fixed IP-address is used)
192.168.0.1 (default)
nnn.nnn.nnn.nnn
Web server port
Sets the port number for the Internal webserver.
This port number often has to be changed if port 80
already is used by other equipment.
80 (default)
Eth-type
Type of Ethernet connection:
Auto
Auto, prefer 10 Mbit (default)
10HDX*
10FDX*
100HDX*
100FDX*
Auto prefer 10 Mbit is default as more speed is not
needed and the emissions from a 10 Mbit LAN is
much less than from a 100 Mbit LAN
(*) If you use fixed settings you must have a