COPYRIGHT 2011 MicroBee Systems Corporation. PCFW-104 M-Series Radio Modem PC/104 Interface User’s Manual CAGE Code 3DPE9 ALL RIGHTS RESERVED However, any part of this document may be reproduced, provided that MicroBee Systems Corporation is cited as the source. The contents of this manual and the specifications herein may change without notice. TRADEMARKS Windows® is a registered trademark of Microsoft Corporation. ROM-DOS is a trademark of Datalight. QNX is a trademark of QNX Software Systems, Ltd ...
NOTICE TO USER . . . . . . . . . . . . . ............................................................................................. . . . . . The information contained in this manual is believed to be correct. However, MicroBee Systems assumes no responsibility for any of the circuits described herein, conveys no license under any patent or other right, and makes no representations that the circuits are free from patent infringement.
destroyed when the power to the card is applied. This is due to the fact that the input current biases the IC so that it acts as a forward biased diode on power-up. This type of failure is typical on serial interface chips. Hot insertion Plugging cards into the card cage with the power on will usually not cause a problem. (MicroBee urges that you do not do this!) However, the card may be damaged if the right sequence of pins contacts as the card is pushed into the socket.
OVERVIEW . . . . . . . . . . . . . ............................................................................................. . . . . . The PCFW-104 PC/104 FreeWave Data Radio is a PC/104 Bus Compliant 8 BIT interface that allows the FreeWave Model FGRM-511X005 900 MHz data radio to be easily installed on any PC-104 stack. The PCFW-104 is fully PC/104 compliant in all aspects EXCEPT height. The PC/104 specifications calls for a height of 0.4 inches.
TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . ............................................................................................. . . . . . Baud Rate The PCFW-104 is fully 16C550A compliant and supports software selectable baud rates of 300, 1200, 2400, 4800, 9600, 19.2K, 38.4K, 56K and 115.2K. Environmental -40° to 85° C operating. -50° to 90° C non-operating. RH 5% to 95%, non-condensing. Power Specification 5V +/– 5% at 50 mA max. 12V +/- 5% at 500 mA, Radio powered by PC/104 Bus.
98, ME, NT, 2000 and XP may limit your IRQ selection without aftermarket drivers. This is usually not required unless all IRQ’s supported by the OS are already allocated. Note PC/104 CPU manufacturers vary in implementation of the interrupt interface. Most use pullups on the interrupts. This allows a board to drive low or tristate float high the interrupt lines preventing damage if two boards conflict. The PCFW-104 uses the tristate scheme. On a few motherboards the manufacturers use pulldown resistors.
Radio Power In order to provide maximum flexibility for the user the PCFW-104 allows for powering of the Radio Module from either the PC/104 Bus 12 VDC supply or an external 6-30 VDC source. PC/104 Bus Power Place jumper JP3 in the INT position (jumper nearest PC/104 Connector). The radio module is now powered from the PC/104 bus an no further connections are required. It is important to be sure that the 12 VDC bus power source has sufficient current to supply the radio.
Testing Installation NOTE Refer to the FreeWave Radio Users manuals for proper radio operation and setup. Once the unit is installed it is recommended that the unit be tested using a simple communications program such as Hyper Terminal under windows. Open the communications program and select the proper COM port. Set the communications parameters to 19,200 Baud, 8 Bits, No Parity, 1 Stop Bits (19200,N,8,1) and press the setup button. The FreeWave Setup Menu should come up on the screen.
Fig 1 PCFW-104 Setup . . . . . . . . . . . . . ............................................................................................. . . . . . WARRANTY . . . . . . . . . . . . . ............................................................................................. . . . . . MicroBee Systems Corporation (MicroBee), warrants that it’s standard hardware products will be free from defects in materials and workmanship under normal use and service a period of one year from date of purchase.
2. personnel, unless Buyer has properly altered or repaired the products in accordance with procedures previously approved in writing by MicroBee. 3. Products which have been subject to power supply reversal, misuse, neglect, accident, or improper installation. 4. The design, capability, capacity, or suitability for use of the Software. Software is licensed on an ”AS IS” basis without warranty.
NOTE For products under warranty, the customer pays for shipping to MicroBee. MicroBee pays for shipping back to customer. Other conditions and limitations may apply to international shipments. NOTE PRODUCTS RETURNED TO MICROBEE FREIGHT COLLECT OR WITHOUT AN RMA NUMBER CANNOT BE ACCEPTED AND WILL BE RETURNED FREIGHT COLLECT. RETURNS There will be a 15% restocking charge on returned product that is unopened and unused, if MicroBee accepts such a return. Returns will not be accepted 30 days after purchase.
WWW.MICROBEE-SYSTEMS.