Instruction manual
106
RFT9739 Rack-Mount Transmitter Instruction Manual
Replacing Older Transmitters
continued
Figure F-2. RE-01 Remote Electronics Unit terminals
Table F-2. RE-01 to RFT9739 terminal conversions
Take the wire from
RE-01 terminal
number:
...and connect it to
RFT9739 terminal
number
Wire color
(Micro Motion
color-coded cable) Function
1 CN1-Z2 Brown Drive +
2 CN1-B2 Red Drive –
3 CN1-B6 Orange Temperature –
4 No connection — —
5 No connection — —
6 CN1-B4 Yellow
[1]
[1]
Shield wire from orange/violet pair.
Temperature lead length compensation
7 CN1-Z8 Green Left pickoff +
8 CN1-Z10 Blue Right pickoff +
9 CN1-Z6 Violet Temperature +
10
11
12
See RFT9739 power-supply wiring
and grounding instructions (
Chapter 4
)
13 CN2-D14 or CN2-Z14 — Signal ground
14 CN2-Z26 — VF +
15 No connection — —
16 CN2-D30 — PV –
17 CN2-Z30 — PV +
18 CN2-D26 — Return
19 CN2-D24 — Freq