Instruction manual

26
RFT9739 Field-Mount Transmitter Instruction Manual
Output Wiring
continued
Figure 5-1. Output terminals
Table 5-1.
Output wiring terminal
designations
Terminal Function
14 Frequency output, DC supply voltage
15 and 16 Frequency/pulse output
17 and 18 Primary variable (PV) mA output
19 and 20 Secondary variable (SV) mA output
21 and 16 Remote zero input
22 and 16 Control output
23 Signal ground
24 and 23 Temperature output
25 and 23 Tube period output
26 and 27 RS-485 I/O
P DC power to pressure or DP transmitter
S mA input from pressure or DP transmitter
HART Communicator hookup loops, same as PV mA output circuit