Instruction manual
Transmitter Mounting
continued
RFT9739 Field-Mount Transmitter Instruction Manual
13
Output Wiring Startup TroubleshootingBefore You Begin Getting Started Mounting
Power-Supply and
Sensor Wiring
3.3 Mounting to an instrument
pole
Follow these guidelines and refer to
Figure 3-2
to mount the transmitter
to an instrument pole:
• Use two 5/16-inch U-bolts for 2-inch pipe, and four matching nuts, to
mount the transmitter to a rigid instrument pole. Use U-bolts and nuts
that can withstand the process environment. Micro Motion does not
supply U-bolts or nuts.
• The instrument pole should extend at least 12 inches (305 mm) from a
rigid base, and be no more than 2 inches (50.8 mm) in diameter.
Figure 3-2. Instrument-pole mounting
2 13/16
(71)
2X
5/16
(8)
4X
8 3/8
(213)
2X
2X
5/16"-18 U-bolt
for 2-inch pipe
Power-supply
wiring conduit
Output wiring
conduit
Sensor cable
wiring conduit
Dimensions in
inches
(mm)
2-inch pipe