Instruction manual
RFT9739 Field-Mount Transmitter Instruction Manual
109
Index
continued
Grounding
18–20,
20
power supply and
18,
19
H
Handbook 44
custody transfer event registers
56
security mode 8
6
HART Communicator.
See also
HART protocol
connecting to transmitter
29
66–67
custody transfer event registers
56
diagnostic messages
65
fast key codes
93
instruction manual
86
interrogation with
66
master reset
74
menu trees
91–93
specifications
communication output
79
troubleshooting with
66
HART protocol.
See also
HART Communicator
communication configuration
using display
51–55
using switches
5, 9–10
mA outputs
27–29
master reset default values
75
multidrop network
Bell 202
48
RS-485
47
Hazardous areas
agency approvals
82
Europe
4
installing in
3
order an approved transmitter
85
Host controller.
See
Multidrop network
Humidity limits
81
I
Identifying transmitter version
97
Initialization
51
Input.
See
Pressure transmitter
Instruction manuals
list of
86
Instrument pole mounting
13
Intrinsically safe installations
3
grounding
18,
19
, 19
wiring guidelines
15, 18, 22
K
Knob.
See
Scroll and Reset knobs
L
Labels
maintenance
95
Lead length compensation
temperature return wiring terminal
22
LED.
See
Diagnostic LED
Lockout clamp for CENELEC
17,
17
Low-flow cutoff specification
80
Low-voltage directive.
See
CE
M
mA outputs
27–29
.
See also
Outputs
AMS modem
29
Bell 202 multidrop network
48
communication configuration
9–10
fault indication
65
HART Communicator
29
master reset default value
75
performance
27,
27
ProLink PC interface
29
scaling
9
security mode 8
6
specification
78
switches
5, 9–10
temperature effect on
81
test
66, 80
trim
66
wiring
27–29,
28
Master reset
default characterization and configuration values
75
procedure
74
security mode 8
6, 10
Menu trees for HART Communicator
91–93
fast key codes
93
Message display.
See
Diagnostic messages
Modbus protocol
communication configuration
using display
51–55
using switches
5, 9–10
instruction manual
86
master reset default values
75
multidrop network
47
Model 3300
wiring
43
Model 3350
wiring
43
Model number matrix
85–86
Mounting
11–13
Msg indicator.
See
Diagnostic messages
Multidrop network
Bell 202
48
RS-485
47
N
NAMUR standard
27
National Institute of Standards and Technology
custody transfer event registers
56
security mode 8
6
Network.
See
Multidrop network
NFC Net Flow Computer
wiring
41
NIST.
See
National Institute of Standards and Technology
NOC Net Oil Computer
AC-powered wiring
42
DC-powered wiring
42
Normal resistance range for flowmeter circuits
73
O
Optional display.
See
Display
Ordering information
85–86
instruction manuals
86
Outputs
control
35–37,
35
open collector mode
36,
37
fault indication
65
frequency/pulse
30–56
constant current
32,
32
default configuration
31
increased current
31,
31
open collector mode
33,
34
test
66
wiring
31