Installation guide
22 Model 3500 Transmitters or Model 3300 Peripherals - Panel Mount
Wiring
Figure 3-12: Shield drain wires wrapped twice around exposed shield foil
e. Place the shielded heat shrink over the exposed shield drain wires. The tubing
should completely cover the drain wires.
f. Without burning the cable, apply heat (250 °F or 120 °C) to shrink the tubing. See
Figure 3-13.
Figure 3-13: Shielded heat shrink covering exposed drain wires
g. Position the gland clamping insert so that the interior end is flush with the heat
shrink.
h. Fold the cloth shield or braid and drain wires over the clamping insert and
approximately 1/8 inch (3 mm) past the O-ring. See Figure 3-14.
Figure 3-14: Folded cloth
i. Install the gland body into the core processor housing conduit opening. See Figure
3-15.