Operating instructions

5. Installation MICRO PANEL XV-102 3.5"
20 M002869-02, 07/2009
5.2 Requirements for the place of installation
#
##
# Approvals:
The device must only be used in locations that are approved for the device. See the markings on
the nameplate and Chapter 9. Technical data, " 49.
#
##
# Power supply:
The power supply must comply with the requirements stated in Chapter 9.5.1 Power supply, " 52.
5.2.1 Requirements for the mounting position
The device is designed for mounting in control cabinets, control panels or control desks. It can be
mounted horizontally or vertically. The following requirements must be fulfilled when selecting a suitable
mounting position:
#
##
# The display should not be exposed to direct sunlight (the UV component of sunlight reduces the
lifespan of the device).
#
##
# If the device is to be used in potentially explosive atmospheres, the device must not be subjected
to hazardous knocks.
#
##
# If possible, the operating elements on the service side of the device and the cable connections
should also still be accessible after the device has been mounted.
#
##
# The ambient conditions stated must be observed. See Chapter 9.9 Ambient conditions, " 53.
#
##
# Sufficient ventilation (cooling) must be ensured by means of:
#
##
# Clearance of at least 3 cm to the ventilation slots
#
##
# Clearance of at least 15 cm from heat radiating components such as heavily loaded trans-
formers
#
##
# The expected temperatures should be within the permissible range. See Chapter 9.9 Ambient
conditions, " 53.
#
##
# Properties of the mounting surfaces:
#
##
# Material thickness at the mounting cutout 25 mm
#
##
# Flatness 0.5 mm
(this requirement must also be fulfilled when the device is mounted!)
#
##
# Surface roughness Rz 120