Hardware manual

MICRO PANEL Quick Start Guideline XV-2xx Systems
The first PLC Program
Put the cursor in the variable that you would like to allocate.
Click in the menu EditÆAuto declare…
- The window “Declare Variable” will open.
Select the classClass“ VAR_GLOBAL“.
Select under “Variable List” the variables list you would like to allocate to.
Confirm the adjustments with OK.
Compile and download the PLC project to the unit:
Click in the menu ProjectÆRebuild All to compile the project.
Click in the menu OnlineÆLogin to log into the unit.
Click in the menu OnlineÆStart to start the PLC project on the unit.
Click in the menu Online Æ Create Boot project to save the project on the unit.
Click in the menu OnlineÆLogout to log off of the unit.
The performance of visualization (Refresh cycle) can be increased by grouping the
individual SPS variables in data structures „Struct“ or data fields „array“. The data
structures and data fields are transferred in a communication package between the
MXpro runtime system and Galileo runtime system, individual variables are sent in
individual packages behind each other.
Further topics to PLC you may find in the helpful MXpro documentation.
Subject to technical changes
M001789-01.DOC