User manual

Microgate MicroGraph LED User Manual Page 74 of 88
Internal Clock Display (RTC) Active Object
Command code
N
Data area
Item
Length (bytes)
Notes
Display format
1
1 (binary) = HH:MM:SS
2 (binary) = MM:SS
3 (binary) = HH:MM (24h)
4 (binary) = HH:MM (12h)
Delay
4
long integer (31 bit + symbol) with advance or delay
of the displayed time with respect to the internal clock
(Real Time Clock), expressed in thousandths.
Internal Clock Display (RTC) Active Object
Command code
N
Data area
Item
Length (bytes)
Notes
Display format
1
1 (binary) = HH:MM:SS
2 (binary) = MM:SS
3 (binary) = HH:MM (24h)
4 (binary) = HH:MM (12h)
Delay
4
long integer (31 bit + symbol) with advance or delay
of the displayed time with respect to the internal clock
(Real Time Clock), expressed in thousandths.
Write Scrolling String Active Object
Command code
O
Data area
Item
Length (bytes)
Notes
Writing width
2
Writing width in pixels (binary word)
Display delay
2
Scrolling delay (Frame to Frame) in hundredths (white
word)
Display width
1
Display width in pixels (binary)
Writing
?
From 1 to 255 characters + 'null terminator'
Write Fixed String
Command code
G
Data area
Item
Length (bytes)
Notes
String
<=81
Characters to display (with null terminator)