User manual

Microgate MicroGraph LED User Manual Page 37 of 88
SS = 12 Set the seconds with START-MODIFY
Press LAP-SETUP
Set Sync.Time
mm = 234 Set the thousandths with START-MODIFY
Press LAP-SETUP
Now, if the time for synchronization is over, MicroGraph waits for a START (from button or input) for
synchronization and displays:
Set Sync.time
02:44:01
Start to Sync. Press START-MODIFY or send START signal from input.
NOTE: When setting the time for synchronization, MicroGraph shows the time of first setting. If no value is
modified, time is not changed and continues to run as if Setup had not been used. This makes it possible to
edit the other parameters without losing synchronization.
2.6.2 START TIME 2
The way this program functions is similar to that of the previous program. In this case however, at each
start the starting time (minutes, seconds and thousandths) and the deviation in minutes, seconds and
thousandths relative to the scheduled starting time (with - for early start and + for delayed start) are
displayed in sequence.