User manual
Microgate MicroGraph LED User Manual Page 33 of 88
Figure 29
In the example shown in Figure 29, 2 Polifemos connected to EncRadio with Banana Cube have
been used.
It is important to point out that if the EncRadios have been set to LONG transmission signals, the
time for covering the length base cannot be less than 3 seconds, whereas using SHORT signals the
time cannot be less than 1 second.
Figure 30
Use of 2 Polifemo photocells and 1 EncRadio. The first photocell must be connected (2-meter
CAB050 cable or 20 meter CAB048 cables) to the Red and Black banana jacks of the Encradio and
the second to the Green and Black banana jacks. The rotating selector for the selection of the
signal on the Encradio must be set to LAP E. With this option it is not possible to exploit the
bidirectionality of the system or to have more than one competitor in the measurement base.
DECRADIO
POLIFEMO
ENCRADIO (Stop)
BANANA CUBE
POLIFEMO
ENCRADIO (Lap qualsiasi)
BANANA CUBE
INGRESSO RADIO
uGRAPH
DECRADIO
POLIFEMO
ENCRADIO
BANANA VERDE IN
BOCCOLA ROSSA
BANANA NERA IN
BOCCOLA NERA
BANANA VERDE IN
BOCCOLA VERDE
BANANA NERA IN
BOCCOLA NERA
BANANA VERDE IN
BOCCOLA VERDE
BANANA NERA IN
BOCCOLA NERA
CAB048 o CAB050
POLIFEMO
BANANA VERDE IN
BOCCOLA VERDE
BANANA NERA IN
BOCCOLA NERA
INGRESSO RADIO
uGRAPH