User manual

Microgate MicroGraph LED User Manual Page 30 of 88
2.4 TIMER (CHRONOMETER)
In this mode MicroGraph works as a typical 1/100 second precision chronometer.
Pressing Start (manual, from input or via radio) the chronometer begins to count.
With Lap (manual, from input or via radio) the chronometer displays an intermediate
time for 5 seconds.
The chronometer is stopped using the manual Start/Stop or via radio.
At this point it is possible to reset the chronometer with a further Lap.
Without reset the chronometer starts from the displayed value.
If the AutoReset time has been set, after each Stop (or manual Start) the chronometer is reset
after a given amount of time.
RADIO: The Timer program can be used also with a Linkgate radio system once the radio channel
has been set correctly. The MicroGraph display board works also with START, LAP, and STOP
signals from Linkgate.
2.4.1 SETUP
Keep the LAP-SETUP pressed for at least 2 seconds to enter the Setup. Press START-MODIFY to change the
displayed values.
Configuration
Normal | Over 24H | Until 24H Set the desired mode:
Normal = the chronometer starts from 0:00
Over 24H = the chronometer continues infinitely and after 24h displays
time as 24:00:01
Until 24H = the chronometer stops after 24h.00.00
Press LAP-SETUP
Advanced Setup ? Press any key to continue.
Yellow = Yes Press LAP-SETUP to enter the general setup (see par. 2.1)
Green = No Press START-MODIFY to scroll the setup of the current program
Set Starttime
HH= 0 Set the hours
Press LAP-SETUP
Set Starttime
MM= 0 Set the minutes
Press LAP-SETUP
Set Starttime
SS= 0 Set the seconds
Press LAP-SETUP