User manual
Microgate MicroGraph LED User Manual Page 28 of 88
2.2.1 SETUP
Keep the LAP-SETUP pressed for at least 2 seconds to enter the Setup. Press START-MODIFY to change the
displayed values.
Advanced Setup ? Press any key to continue.
Yellow = Yes Press LAP-SETUP to enter the general setup (see par. 2.1)
Green = No Press START-MODIFY to scroll the setup of the current program
Font
Regular|Narrow Set the default font (normal or narrow)
Press LAP-SETUP
Row
0...15 Set the row address (0 = first row)
Press LAP-SETUP
Column
0...3 Set column address (0 = first column)
Press LAP-SETUP
X Offset
0...384 Set the number of X Offset LEDs. All commands (with the ALPHA protocol)
will be shifted to the left by a certain amount of LEDs.
Press LAP-SETUP
Baud
1200…230400|RADIO Set the speed of the serial port applying one of the default values ('1200',
'2400', '4800', '9600', '19200', '38400', '38400', '57600', '115200', '230400',
'RADIO'). Specifying 'RADIO' communication via modem with Linkgate is
activated.
Press LAP-SETUP
Green to Default
Press the green START-MODIFY button to reset the display board to the
default values, or press the yellow LAP-SETUP button to accept the entered
values.