User manual

Microgate MicroGraph LED User Manual Page 22 of 88
1.8 HARDWARE RESET
If the display board stops responding to commands (e.g. entering the Setup menu as described in
par. 2.1), a Strong Reset can be carried out choosing to reset all values to the default parameters
(Factory Settings).
The steps to carry out are the following:
Turn off the display board by pressing the Power (Off) button.
Press simultaneously the START-MODIFY and LAP-SETUP buttons to turn on the display board
(Power -> On)
During the first boot phase, when the first 4 LEDs (2x2) in the upper left corner are blinking,
keep the two buttons pressed.
When the blinking LEDs are 6 (3 x 2) release the two buttons.
After a few moments the software asks if you want to restore the factory settings (Reset
Setting? Yellow=Yes) or use the stored settings. Press LAP-SETUP to reset all values
to the initial conditions.