5. EVENT SETUP
5.1 ALARM SETUP: Setup ALARM CONDITION
5.1.1 ALARM INPUT: Setup ALARM INPUT ON/OFF
Select 'ON' for ALARM EVENT RECORDING.
5.1.2 INPUT TYPE: Select alarm input type between ‘Normal Open’ and ‘Normal Close’
NC: NORMAL CLOSE
NO: NORMAL OPEN
5.1.3 ALARM OUTPUT:
ALARM INPUT ALARM OUTPUT
Normal Open Normal Open
A
larm input type is Normal Open.
The device connected to alarm output is in ‘OFF ‘status
and turns ON when events occur.
Normal Open Normal Close
A
larm input type is Normal Open.
The device connected to alarm output is in ‘ON ‘status
and turns OFF when events occur.
Normal Close Normal Open
A
larm input type is Normal Close.
The device connected to alarm output is in ‘OFF ‘status
and turns ON when events occur.
Normal Close Normal Close
A
larm input type is Normal Close.
The device connected to alarm output is in ‘ON ‘status
and turns OFF when events occur.