Specifications
17
FIGURE 15
This Kit Includes:
1 ea. 38324-01 Motor Shroud
15 ft. P3553 Self-Adheasive Foam
12 ea. P3543 Self-Tapping Screws
INSTALLATION:
1. Remove parts from package and inspect for any possible damage incurred during shipping.
2. Examine the vertical braces on each side of the motor that run the full length of the motor blower
assembly. If each of the vertical braces have six (6) 7/32” diameter holes proceed to Step 6. If the
braces do not have the six (6) 7/32” diameter holes proceed to Step 3.
3. Place the motor shroud, as shown in Figure 15 below, over the motor having located the slotted hole of
the motor shroud on the right hand side. This will allow the wiring conduit to clear the motor shroud.
4. With the shroud in place mark the centers of the six (6) holes in each vertical brace. On the bottom right
hand side of the shroud the electrical box will prevent you from marking two (2) of the holes. The two
(2) holes may be omitted.
5. With the holes having been marked remove the motor shroud and use a 7/32” diameter drill bit to drill
through the braces.
6. Apply the self-adheasive foam to the vertical braces as shown in the picture below.
7. Re-install the motor shroud around the motor and attach using the twelve (12) self-tapping screws
provided.
8. The four bolts and small cover on the back of the motor shroud may be removed to allow you to check
forproper rotation of the motor blower. When proper rotation has been checked re-install the cover.
RP DUST COLLECTOR
MOTOR SHROUD INSTALLATION
SELF-ADHEASIVE FOAM
7/32” DIA. HOLE TYP. 12 PLCS.
MOTOR SHROUD
SELF-TAPPING SCREWS
ELECTRICAL BOX