Specifications
15
RP DUST COLLECTOR
INLET PLENUM INSTALLATION PROCEDURE
This Kit Includes:
1 ea. 38292-01 RP Inlet Plenum Assembly
1 ea. P3653 Hardware Package - Containing:
4 ea. P261 5/16-18 X 1/4 Bolt
4 ea. P249 5/16” Lock Washer
4 ea. P233 5/16” Flat Washer
24 ea. P2543 1/4” X 1” Self-Tapping Screw
11 ft. P3686 3/16” X 1” Self-Adheasive Foam
INSTALLATION:
1. Remove inlet plenum from skid and inspect for any possible damage incurred during shipping.
2. Place self-adheasive foam on the outside of the inlet plenum hole pattern.
3. Place inlet plenum on top of dust collector and using the four (4) bolts, fl at washers and lock washers
provided to attach the inlet plenum at the four corners.
4. Use the twenty-four (24) self-tapping screws to complete the installation of the inlet plenum..
5. Three cap plates can be removed and reinstalled to allow you to use the opening best suited for your
installation.
FIGURE 12
BOLT
SELF-TAPPING
SCREWS
SELF-ADHEASIVE
FOAM