Specifications
14
RP DUST COLLECTOR
PHOTOHELIC KIT INSTALLATION PROCEDURE
This Kit Includes:
1 ea. 38293-01 Photohelic Mounting Bracket
1 ea. P3643 0-10” w.c. Photohelic Gauge
2 ea. P2098 1/8” Male x 1/4” Barb Fitting
4 ea. P3543 1/4”-14 x 1 Self-taping Screw
10 ft. P1848 1/4” Clear Tubing
NOTE: When using a Photohelic on a dust collector installed outdoors, the gauge can not be mounted on the
unit. It must be mounted indoors. The gauge is not rated for outdoor use.
INSTALLATION:
1. Remove parts from package and inspect for any possible damage incurred during shipping.
2. Turn off dust collector and disconnect power to the unit.
3. Remove the plastic cover on the back of Photohelic Gauge.
4. Mount the Photohelic Gauge into the Photohelic Mounting Bracket and place the (2) male barb fi ttings
in the pressure ports located on the side of the Photohelic Gauge.
5. Remove cover from electrical box so that wiring diagram on back of cover can be used.
6. Remove the two red wires that are connected to the Timer Board Pressure Switch Input and Relay CR1.
7. Wire the Photohelic Gauge as the electrical diagram shows in Detail “A” (see page 10) using the 3/4”
conduit opening on the Photohelic and the 3/4” knockout located on the electrical box. (Wire and
conduit supplied by others.)
8. Replace the cover back onto the Photohelic Gauge and mount the bracket using the (4) 1/4” self-taping
screws.
9. Using 1/4” clear tubing (Additional length can be purchased) connect the “LOW” pressure port on the
gauge to the clean air plenum and “HIGH” pressure port to the dirty air plenum.
10. You must place the enable/disable switch located on the timer board to the “DISABLE” position. This
will disable the after-pulse mode of the timer board.
11. Replace the cover on the electrical box and reconnect the power to the unit.
12. The right set point dial of the gauge should be positioned at the fi lter differential set point you want the
Roto-pulse system to be enabled. The left should be positioned at the fi lter differential set point you
want the Roto-pulse system disabled.
LOW HIGH
FIGURE 11