SILENCER INSTALLATION PROCEDURE (64” LEGS ONLY)
This Kit Includes:
1 ea. 38275-01 RP Silencer Assembly
INSTALLATION:
1. Remove silencer from skid and inspect for any possible damage incurred during shipping.
2. If cross bracing has been installed remove bracing on the motor blower side and one of the remaining
two sides.
3. Remove all of the self-tapping screws on the exhaust grill with a 3/8” nut driver and save (NOTE: DO
NOT REMOVE EXHAUST GRILLE).
4. Remove the two bolts in the exhaust grille that are closest to the legs with a 1/2” wrench and save.
5. Install the silencer with the screws and bolts removed in steps 3 and 4. The side of the silencer with
self-tapping screws should be on the side of the motor blower for installation.
5. Re-install the cross bracing removed from the side and the motor blower side in step 2.
FIGURE 9
IMPORTANT: DO NOT REMOVE EXHAUST GRILLE FOR THIS INSTALLATION
STEP 2
STEP 5
STEP 6