OPTIONAL SILENCER INSTALLATION
1. Remove Exhaust Grille from unit as shown in FIG. 7.
2. Slide Silencer over Blower Assembly.
3. Align holes from Silencer with those located on sides of the Blower Assembly.
4. Attach Silencer to Blower Assembly using ” bolt, lockwasher, & at washer.
5. Center Exhaust Grille over hole in Silencer & attach using 8-32 self tapping machine screws.
BLOWER ASSEMBLY
3/8” BOLT
LOCK WASHER
FLAT WASHER
SILENCER
EXHAUST GRILLE
8-32 SMS
FIG. 7