Specifications

MICRO AIR® MX3510
CLEAN AIR SYSTEMS
6
MX3510 MICRO AIR®
CLEAN AIR SYSTEMS
7
FILLING OF RCM MODULES
1. Remove bulk charcoal or purasorb from shipping carton by removing plastic bags within carton.
2. set module on level surface. Remove ll cover by removing six 10-32 phillip head screws, that secure cover. Set cover aside
(See FIG. 6).
3. Open the plastic bag by removing the tape, holding close. Pour the material from the plastic bag into the module through the
slots. It may be necessary to slightly shake the module to assure an even ll. Excess material may be saved by resealing the
plastic bag.
NOTE: Slow pouring will minimize dust that will be present during pouring.
4. After lling module, discard plastic bag and reinstall ll cover removed in step 2.
NOTE: The MX3510 requires two modules when used as a second main lter and four modules when used as a rst and second
main lter.
5. With Filter track in place and handle pulled out away from cabinet load RCM / HEPA modules into track.
NOTE: Make sure modules are seated properly into track and stacked evenly.
6. With lters in place rotate handle 90° and lock lter modules in place.
POUR MATERIAL
INTO SLOTS
FILL COVER
FIG. 6