Specifications

MICRO AIR® MX3510
CLEAN AIR SYSTEMS
4
MX3510 MICRO AIR®
CLEAN AIR SYSTEMS
5
UNITS WITH HEPA OR CHARCOAL OPTIONS FOR
MX3510
1. On units with optional HEPA or charcoal lters, an adjustable lter
track kit is used to complete the seal of these lters to the lter
stop (See FIG. 4 & 5). If the unit was ordered with either a HEPA
or charcoal lter, this adjustable lter track kit was included with
the unit. If a HEPA or charcoal lter is ordered as an after-market
item, the adjustable ler track kit should be ordered as well. Order
Part No. 38036-01.
Each lter track kit is supplied with:
j 1pc. Filter track
k 2pc. Supports
l 1pc. Handle
m 4pc. Retaining brackets
n 1pc. Door stop bracket
o 3pc. Horizontal support
p 16pc. #8-32 self tapping hex screws.
HEPA OR CHARCOAL AS SECOND MAIN FILTER
1. Place supports k in cabinet at a dimension of 13 ” and
secure with self tapping screw.
2. Place track j in cabinet so it rests upon supports and ”
diameter pin is located behind brackets on supports.
3. Place handle l on supports so that it rests in notches.
4. Lock ” diameter rods on handle and track in place with
brackets m and self tapping screws.
5. Place handle stop bracket n at a dimension of 15 ” and
secure with self tapping screws. This is to keep handle
from rotating past 90° and allowing lter to loosen.
6. Place horizontal supports o in 2 places. One piece at
a dimension of 5” on bottom of cabinet and one piece at
a dimension of 10” on rear of cabinet with self tapping
screws.
13”
10”
5”
5
3
1
2 TYP. 2 PLCS.
4
TYP. 4 PLCS.
6
6
RCM
FIG. 4