EasyTouch RV 359 Manual

7
©2022 Micro-Air Corp May 20, 2022, revision 1.3
Thermostat Setup
Setting the Available Sources
Press the settings button on the main screen.
Use the back and next buttons to locate the switches icon. Press the icon to configure the
modes from the available sources.
Press the icons to select or deselect the mode. A red circle with a line
through it will appear over the source when it is deselected.
Gas Heat Override Enable/Disable
You can enable or disable gas heat override by tapping the
Enable/Disable button under the Auto Gas Changeover heading. When
enabled, all of your available heat modes will act in stages based on how
far the inside temperature is from the set-point. See section Gas Heat
Override for more details. Most users will leave this setting enabled.
Invert On/Off
This setting changes the polarity of the furnace from +12 volt active
to ground active. Most users will set it for invert ON. Setting the incorrect
setting will cause the furnace to operate all the time.
Connecting remotely
EasyTouch RV can be operated entirely by the touchscreen, however you can
also communicate, monitor, and modify operation of it wirelessly using the EasyTouch
RV application. Some extra features will require a wireless connection and is described
in their sections. See section Working Wirelessly for details.
EasyTouch RV icon
ENABLED
Gas Heat Override
Enable/Disable